Functional Features
Modular design, with each module having 8 independent channels.
Each channel can be arbitrarily set to modes such as constant – current charging, constant – voltage charging, constant – power discharging*, constant – resistance discharging*, direct – current internal – resistance testing*, and standing still, etc.
Each channel can detect different types of batteries and work completely independently in different modes without interfering with each other.
The channels have complete multi – level software and hardware protection.
There are independent hardware constant – current sources and constant – voltage sources.
Support over – discharge protection.
Support online correction of current and voltage accuracy, enabling users to “test while calibrating”.
Technical Parameters
Input |
Power | CT3002K 5V 1A&6A: 380W
CT3002K 5V 1A&12A: 800W |
|||
Power Source | AC220V50HZ/110V60HZ | ||||
Resistance | ≥1MΩ | ||||
Voltage |
Voltage Measurement | 5V | |||
Voltage Output Range | CT3002K 5V 1A&6A Charge: 0V ~ 5V
CT3002K 5V 1A&12A Charge: 10mV ~ 5V (adjustable to 0V) |
CT3002K 5V 1A&6A Discharge: 0V ~ 5V
CT3002K 5V 1A&12A Discharge: 1V ~ 5V |
|||
Resolution | 5 significant digits (automatic) | ||||
Output Method | Four – electrode (supports reference electrode testing) | ||||
Computer System Time | ±1 second (without cumulative error) | ||||
Data Recording | Time change Δt: 0.1s to 60000s
Voltage change ΔU: 10mV to 5V Current change ΔI: 2mA to 6A/12A |
||||
Time | current response time | <5ms(10%~90%) | |||
Equipment sampling time | Equipment sampling time | 100ms | |||
Charging |
Charging Modes | Constant – current charging, constant – voltage charging, constant – current constant – voltage charging, constant – power charging, constant – resistance charging, multi – rate charging. | |||
Discharging Modes | Constant – current discharging, constant – voltage discharging, constant – power discharging, constant – resistance discharging, multi – rate discharging (parallel constant – voltage discharging of channels is not supported). | ||||
Cut – off Conditions | Step time, voltage, current, capacity, energy, – ΔV, charge – discharge cycle, tx, Cx, N1, N2, current multiplier, Coulomb efficiency, capacity retention rate, temperature, voltage. | ||||
Charge/discharge switching | Delay time | <10ms | |||
DCIR Test | Support | ||||
Protection Conditions |
Voltage Protection | Over – voltage protection, under – voltage protection. | |||
Current Protection | Charging current protection, discharging current protection. | ||||
Capacity Protection | Charging capacity protection, discharging capacity protection. | ||||
Trend Protection | During constant – current charging, monitor voltage protection (cannot decrease).
During constant – current discharging, monitor voltage protection (cannot increase). During constant – voltage charging, monitor current protection (cannot increase). |
||||
Related Channel Protection: | Maximum and minimum voltage protection for voltage auxiliary channels.
Maximum and minimum temperature protection for temperature auxiliary channels. |
||||
Hardware Protection | Anti – reverse connection protection. | ||||
Cycle | Cycle Times | CT3002K 5V 1A&6A: 1 to 65000 times, total step number 1100, maximum support for 3 – layer nested cycles.
CT3002K 5V 1A&12A: 1 to 65000 times, single – cycle step number 1100, maximum support for 5 – layer nested cycles. |
|||
Channel Number | 8 | ||||
Application Range | It can be used for testing various mobile phone batteries, 3C batteries, etc. | ||||
Channel Control Mode | CT3002K 5V 1A&6A: Each channel can detect different types of batteries and work completely independently in different modes without interference.
CT3002K 5V 1A&12A: Independent control. |
||||
Channel Characteristics | CT3002K 5V 1A&6A: There are independent hardware constant – current sources and constant – voltage sources, support over – discharge protection, support online correction of current and voltage accuracy, enabling users to “test while calibrating”.
CT3002K 5V 1A&12A: Constant – current source and constant – voltage source adopt an independent double – closed – loop structure. |
||||
Noise | CT3002K 5V 1A&6A: <75dB
CT3002K 5V 1A&12A: <65dB |
||||
Communication Mode with Host Computer | CT3002K 5V 1A&6A: Serial communication/TCP
CT3002K 5V 1A&12A: RS422/network port |
||||
Communication Interface | RS422 | ||||
Number of Auxiliary Channels per Channel | Data Export Format | ||||
Data Export Format | CT3002K 5V 1A&6A: EXCEL, TXT, CSV
CT3002K 5V 1A&12A: EXCEL, TXT |
||||
Environmental Requirements | CT3002K 5V 1A&6A: Temperature: – 10 ~ 50°C (23 ± 2°C for best accuracy), Humidity: ≤95% non – condensation
CT3002K 5V 1A&12A: Temperature: – 10 ~ 40°C (25 ± 10°C ensures best measurement accuracy), Relative Humidity: ≤80% non – condensation |
||||
Single – Machine Size | W440 * D446 * H104(mm) | ||||
Single – Machine Weight | Approximately 12kg |