Surface Area and Porosity Analyzer-BSD-PS2

Surface Area and Porosity Analyzer-BSD-PS2

Modular gas – path design.
Anti – pollution device for the degassing position.
Imported double – pressure sensors.
All key components are imported

Category:
Share your love
Share your love

Technical Parameter

Power Supply Voltage: AC220V ± 5%, Power < 1kW
Testing Precision Testing precision, repeatability, and reproducibility error < ± 1
Testing Range Surface: 0.0005m²/g or above

Micropore: 0.35nm – 2nm

Mesopore: 2nm – 50nm

Macropore: 50nm – 500nm

P0 Testing It has an independent saturated vapor pressure (P0) testing station to ensure the high – accuracy of isobaric testing.

 

(Patent Name: Static volumetric method and the analyzer of pore size distribution. Patent No.: ZL20121020136959.X)

Saturated Vapor Pressure P0 Rotation Using a spiral – shaped tube as the P0 saturated vapor pressure tube, connected with the instrument host, can quickly reach the liquid – nitrogen temperature, making the measured saturated vapor pressure closer to the real value. (The effect is the same as the imported equipment, solving the problem of large errors in the P0 test results of domestic straight – tube equipment.) Improve testing precision.

 

(Patent Name: Saturated vapor pressure P0 rotation tube and the static volumetric method and the analyzer of pore size distribution. Patent No.: ZL201620716311.2)

Analysis Station There are 2 stations for sample pretreatment and degassing, 2 stations for sample analysis, and 1 P0 testing station. The analysis station has an independent gas circuit and pressure sensor, supporting completely independent parallel analysis.
Constant – Temperature Device The constant – temperature device can keep the temperature of the sample cell, gas, valve, pipeline, sensor, etc. in the constant – temperature device stable while maintaining the ambient temperature unchanged, reducing the temperature non – uniformity caused by valve heating.

 

(Patent Name: The analyzer of static volumetric method and pore size distribution with a constant – temperature device. Patent No.: ZL201410248783.3)

 

Beishide Instruments’ Self – developed BSM – DS Module

The self – developed BSM – DS module of Beishide Instruments integrates the sample cell, gas circuit, valve, pipeline, sensor, etc. There is no welding seam or seal ring, and the gas circuit connection is seamless. The vacuum degree of the whole system is improved by more than 90%, completely eliminating the leakage point. The overall system leak rate is less than 10 – 10 Pa·m³/s, improving the stability and reliability of the instrument. The gas circuit part of the system is integrally modularized for processing, greatly reducing the failure rate and improving the instrument stability.
Sample Loading Import dual – port pressure sensor, segmented testing: 0 – 100Torr, or 1 – 1000Torr; testing accuracy error < ± 0.15%; Large – pore P0 has real – time testing function, making P0 measurement more accurate at the critical point.

 

(Patent Name: The analyzer of static volumetric method and pore size distribution. Patent No.: ZL20121020136959.X)

Degassing Station Combined with Beishide’s self – developed vortex – type vacuum – pumping physical anti – pollution device, it can completely eliminate sample pollution during the vacuum – pumping process under the current of the existing gas, improving the vacuum – pumping efficiency and shortening the vacuum – pumping time.

 

(Patent Name: The physical anti – pollution device for vacuum – pumping station. Patent No.: ZL201620714986.3)

Vacuum System The instrument is equipped with 2 sets of independent vacuum systems, namely, the degassing system and the analysis system are independent of each other, avoiding cross – contamination of the vacuum system.
Self – intelligent Detection Advanced self – intelligent detection process, which can determine whether the sample tube is installed properly, whether the sample tube is tightened, and whether there is air leakage.

 

 

 

 

Safety Measures

Liquid Nitrogen Cup Anti – explosion: The “safety – lowering” intelligent control mechanism completely eliminates the risk of sample tube explosion caused by liquid nitrogen cup accidental gas expansion.

 

Operation Log: Detailed instrument operation log display and recording, accurate to the second, full – process experimental records can be traced.

 

Automatic Cover – opening: During the testing process, the liquid nitrogen cup will have two lifting actions, and automatic cover – opening can avoid manual waiting, reduce labor intensity, and reduce uncovered temperature – zone volume testing errors.

 

(Patent Name: Cover – opening device and static volumetric method surface and pore size analyzer. Patent No.: ZL2014201048358.4)

Liquid Level Control Liquid nitrogen surface servo – holding system, eliminating temperature – zone volume changes caused by liquid nitrogen evaporation during the testing process, improving testing accuracy.
Ultimate Vacuum Scroll pump, 4×10⁻² Pa, molecular pump (optional).
Liquid Nitrogen Cup 3L large – volume dedicated liquid nitrogen Dewar cup, large capacity with small – diameter Dewar cup has a long holding time of more than 140 hours, no need to add liquid nitrogen for 90 – hour continuous testing
Instrument Specifications Size: Length 58cm, Width 51cm, Height 83cm

Weight: 55kg