Application range:

GSL-1800X is a CE-certified high-temperature tube furnace. Its inner chamber is embedded with a ZrO₂ lining, and the heating element adopts Kanthal Super-1900 molybdenum disilicide rods, enabling the instrument to reach a maximum temperature of 1800℃. The standard configuration of the instrument includes a set of stainless steel vacuum flanges (with stainless steel needle valves and mechanical pressure gauges installed on the flanges) and a standard high-purity alumina furnace tube (60mm O.D x 1000mm L). The temperature control system uses PID 30-segment programmed temperature control, with a temperature control accuracy of +/-1℃. This instrument is widely used for sintering and annealing materials in vacuum or atmospheric protection environments.

Model:

GSL-1800X

Dimension:

1350mm x 520mm x 780mm (L x W x H)

Net weight:

About 150kg

Categories: ,
Share your love

Features

  • CE-certified high-temperature tube furnace; the inner chamber is embedded with a ZrO₂ lining, and the heating element adopts Kanthal Super-1900 molybdenum disilicide rods.
  • Adopts a double-layer shell structure with an air-cooling system.
  • The furnace insulation material uses high-purity alumina fibers, and the interior is embedded with zirconia-lined plates (10mm in thickness, with a refractoriness of 2300℃).
  • Standard configuration includes a pair of stainless steel vacuum flanges (with stainless steel needle valves and mechanical pressure gauges) and a standard high-purity alumina furnace tube (OD 60mm × 1000mm L).
  • Alumina tube plugs should be inserted at both ends of the furnace tube before heating to prevent heat loss and ensure the tightness of the flange.
  • Optional KF25 stainless steel flanges, stainless steel bellows and a digital vacuum display meter are available to achieve a higher vacuum degree more quickly.
  • A variety of flange connectors are available; a KF25 adapter can be selected on the gas outlet flange to connect with the bellows.
  • Equipped with a YD518P temperature controller; PID automatic temperature control system; intelligent 30-segment programmable control; built-in overheat protection and thermocouple fault alarm; temperature control accuracy ±1℃; default DB9 PC communication port. Optional computer temperature control software is available for controlling heating curves and exporting data.

Specifications

Maximum Temperature 1800℃ (<30 minutes)
Long-term Operating Temperature 800-1750℃
Recommended Heating Rate ≤10℃/min below 1400℃; ≤5℃/min from 1400℃ to 1600℃; ≤2℃/min above 1600℃
Heating Zone Length 295mm
Maximum Power 5.2KW
Voltage Single-phase AC220V 50Hz
Heating Elements Kanthal 1900 grade silicon-molybdenum rod, manufactured in Sweden
Furnace Tube (Standard) OD 60mm × 1000mm L
Vacuum Degree 10-3 torr with a dual rotary vane mechanical pump; <10-5 torr with optional domestic or imported high-vacuum units
Dimensions 1350mm × 520mm × 780mm (L×W×H)
Net Weight 150kg
National Patent A new type of high-temperature sintering tube furnace, patent number ZL-2011-2-0077178.8
Certification All electrical components (>24V) are certified by UL/MET/CSA/CE
Warranty One-year warranty and lifetime technical support (consumables such as heating elements, quartz tubes and sample crucibles are not included; damages caused by the use of corrosive gases and acidic gases are not covered)

Operational Notes

  • The internal pressure of the furnace tube must not exceed 0.02MPa. Since the internal pressure of gas cylinders is relatively high, a pressure reducing valve must be installed on the gas cylinder when introducing gas into the furnace tube (recommended range 0.01MPa-0.1MPa).
  • For experiments involving sample heating, it is not recommended to close the gas extraction valve and gas inlet valve at the flange end of the furnace tube. If it is necessary to close the gas valves, the pressure gauge reading must be monitored at all times; if the reading exceeds 0.02MPa, the gas release valve must be opened immediately to prevent accidents such as furnace tube rupture or flange flying off.
  • The gas flow rate should be limited to <200 SCCM (or 200ml/min).